ACLS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Badiou, S.
Right arrow Articles by Cristol, J.-P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Badiou, S.
Right arrow Articles by Cristol, J.-P.
Annals of Clinical & Laboratory Science 39:233-240 (2009)
© 2009 Association of Clinical Scientists

A New DiaSys Colorimetric Assay for Plasma Homocysteine: Application in Diabetic Patients

Stephanie Badiou1,2, Sophie Bariolet1, Anne-Marie Dupuy1, Ariane Sultan2,3, Antoine Avignon2,3 and Jean-Paul Cristol1,2
1 Laboratoire de Biochimie, 3 Service des Maladies Métaboliques, CHU Montpellier, Hôpital Lapeyronie; 2 Université Montpellier I; Montpellier, France

Address correspondence to Professor Jean-Paul Cristol, Biochemistry Laboratory, Lapeyronie University Hospital, 371 Avenue Doyen Gaston Giraud, F34295 Montpellier Cedex 5, France; tel 33 467 338 314; fax 33 467 338 393; e-mail jp-cristol{at}chu-montpellier.fr.

This study was conducted to evaluate the analytical performance of a new colorimetric assay for plasma homocysteine (Hcy) and to determine the influence of the method used on the frequency of hyperhomocysteinemia and on the association between Hcy and biological parameters in diabetic patients. Plasma Hcy was measured in 160 diabetic patients by high performance liquid chromatography (HPLC) in parallel with an automated colorimetric assay (DiaSys Diagnostic Systems GmbH) using the Olympus AU640 and Abbott C8000 analyzers. Plasma glucose, creatinine, folates, vitamin B12, high-sensitivity C-reactive protein (hs-CRP), and blood hemoglobin A1c (HbA1c) concentrations were measured by routine methods. The Hcy concentrations obtained with the HPLC (x) and colorimetric methods (y) were highly correlated (y = 1.032x – 0.65, r2 = 0.884 for AU640; y = 1.028x + 0.87, r2 = 0.934 for C8000). The frequency of Hcy >15 µmol/L was 41.9% by HPLC assay and there was no statistically significant difference using the colorimetric method. Patients with Hcy >15 µmol/L compared to ≤15 µmol/L using HPLC had significantly lower glycemia (p <0.001), lower HbA1c (p <0.001), lower estimated glomerular filtration rate (GFR) (p <0.0001), and lower vitamin B12 levels (p <0.001). All these relationships were also noted when using the colorimetric assay on the Olympus AU640 or Abbott C8000 analyzers. In summary, this study shows that the DiaSys colorimetric assay is suitable for plasma Hcy determinations in routine clinical biochemistry.

Keywords: homocysteine, diabetes, liquid chromatography, colorimetric assay, glomerular filtration rate







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2009 by the Association of Clinical Scientists.