ACLS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Camara, P.
Right arrow Articles by Griffiths, W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Camara, P.
Right arrow Articles by Griffiths, W.
Annals of Clinical and Laboratory Science, Vol 21, Issue 5, 335-339
Copyright © 1991 by Association of Clinical Scientists


Articles

Comparison of a commercial method for total protein with a candidate reference method

PD Camara, C Wright, P Dextraze, and WC Griffiths

The biuret method for total protein has been compared on the Boehringer Mannheim Diagnostics (BMD) Hitachi 717 Analyzer with a candidate reference method in efforts to standardize the BMD method. The methods were compared using 115 paired serum specimens collected during morning rounds at the Roger Williams Hospital. Results from the test method were compared to the reference method using a statistical procedure for quantifying bias between analytical methods. Linear regression statistics were also calculated. The Hitachi 717 biuret method shows no bias when compared to the reference method (z = -0.90), and there is acceptable correlation between the two methods (y = 0.86, m = 0.86, r = 0.896). The Hitachi method is linear to 15.0 g per dL and demonstrates excellent precision (CV less than or equal to 2.14 percent, N = 140). The Hitachi 717 biuret method has been found to be excellent in all respects and its use is recommended as a convenient and accurate means of measuring total protein.


This article has been cited by other articles:


Home page
IOVSHome page
F. Chiambaretta, L. Blanchon, B. Rabier, W. W.-Y. Kao, J. J. Liu, B. Dastugue, D. Rigal, and V. Sapin
Regulation of Corneal Keratin-12 Gene Expression by the Human Kruppel-like Transcription Factor 6
Invest. Ophthalmol. Vis. Sci., November 1, 2002; 43(11): 3422 - 3429.
[Abstract] [Full Text] [PDF]


Home page
Mol Hum ReprodHome page
L. Blanchon, P. Sauvant, C. Bavik, D. Gallot, F. Charbonne, M.-C. Alexandre-Gouabau, D. Lemery, B. Jacquetin, B. Dastugue, S. Ward, et al.
Human choriocarcinoma cell line JEG-3 produces and secretes active retinoids from retinol
Mol. Hum. Reprod., May 1, 2002; 8(5): 485 - 493.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Clin. Nutr.Home page
V. Sapin, M. C Alexandre, S. Chaib, J. A Bournazeau, P. Sauvant, P. Borel, B. Jacquetin, P. Grolier, D. Lemery, B. Dastugue, et al.
Effect of vitamin A status at the end of term pregnancy on the saturation of retinol binding protein with retinol1
Am. J. Clinical Nutrition, February 1, 2000; 71(2): 537 - 543.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1991 by the Association of Clinical Scientists.