ACLS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Saleem, A
Right arrow Articles by Crawford, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Saleem, A
Right arrow Articles by Crawford, E.
Annals of Clinical and Laboratory Science, Vol 13, Issue 2, 115-124
Copyright © 1983 by Association of Clinical Scientists


Articles

Viscoelastic measurement of clot formation: a new test of platelet function

A Saleem, C Blifeld, SA Saleh, DH Yawn, ML Mace, M Schwartz, and ES Crawford

Assessment of platelet function presents a challenge to the investigators in the clinical field. An instrument, Sonoclot, is described which measures changes in the viscoelastic properties (clot impedance on a vibrating probe) of plasma as it is recalcified. Platelet poor plasma (PPP) and platelet rich plasma (PRP) show distinct and characteristic Sonoclot tracings. Tracings of PPP show a lag period and a primary wave. These parameters correspond to recalcification time and fibrin polymerization. Tracings of PRP show, in addition, a secondary wave and a downward wave. These parameters correspond to the incorporation of platelets in the clot and retraction of the clot. The PRP parameters are influenced by the number and quality of the platelets. This instrument was utilized to assess the platelet function in patients after coronary artery bypass surgery (CAB). In 69 patients studied, 20 patients did not have excessive bleeding. The clot impedance tracings in this group were normal. Twenty-four patients had excessive bleeding, normal clot impedance, and coagulation tests indicating the possibility of surgical bleeding. This was confirmed in 22 (92 percent) patients upon exploration to control bleeding. Twenty-five patients had excessive bleeding, normal coagulation tests and abnormal clot impedance suggesting platelet dysfunction. In twenty-one (84 percent) of the patients, transfusion of platelet concentrate controlled the bleeding with corresponding correction of clot impedance. Sonoclot studies are quick and easy to perform, and appear to be a valuable and reliable adjunct in the diagnosis of hemostatic problems after CAB surgery.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1983 by the Association of Clinical Scientists.